 AXICOM
Telecom-, Signal and RF Relays
108-98011 Rev. C
Reed V23100-V4 Relay
Telecom-, Signal and RF Relays
AXICOM
Reed V23100-V4 Relay
108-98011 * Nov. 07 Rev. C * ECOC: JM10
AXICOM
Telecom-, Signal and RF Relays
108-98011 Rev. C
Reed V23100-V4 Relay
Disclaimer
While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, Tyco Electronics does not guarantee that it is error-free, nor does Tyco Electronics make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. Tyco Electronics reserves the right to make any adjustments to the information contained herein at any time without notice. Tyco Electronics expressly disclaims all implied warranties (and all express warranties, except as otherwise stated in this datasheet) regarding the information contained herein, including but not limited to any implied warranties or merchantability or fitness for a particular purpose. It is recommended that you test any new or replacement product before incorporating into a system. The dimensions in this datasheet are for reference purpose only and are subject to change without notice. Specifications are subject to change without notice.
Index
Relay Types DIP Version (flat) DIP Version (high) SIL Version Mini SIL Version Contact Data Insulation General Data High Frequency Data 3 4 6 8 10 11 11 11 11 2 of 13
File No. E 111441
All specifications subject to change. Consult Tyco Electronics for latest specifications.
AXICOM
Telecom-, Signal and RF Relays
108-98011 Rev. C
Reed V23100-V4 Relay
1 and 2 pole relays non-polarized, non-latching ROHS compliant (Directive 2002/95/EC) as per product date code 0501.
Features
* * * * * Direct coil control with TTL-signals possible Highly reliable switching High switching rates Ultrasonic cleanable High vibration and shock resistance
Typical applications
* * * * Incircuit tester Measuring and control systems Telecom equipment Alarm and security equipment
Relay Types
DIP version (flat)
* Standard version * Electrostatic shield between coil and contact * Protective diode * Electrostatic shield and protective diode * Contact arrangement: 1 form a (1 normally open contact) or 1 form c (1 changeover contact)
DIP version (high)
* Standard version * Electrostatic shield between coil and contact * Protective diode * Electrostatic shield and protective diode * Contact arrangement: 2 form a (2 normally open contacts) or 1 form c (1 changeover contact)
SIL version
* Standard version * Protective diode * Contact arrangement: 1 form a (1 normally open contact)
Mini SIL version
* * * * Standard version Protective diode Standard internal magnetic shield Contact arrangement: 1 form a (1 normally open contact) 3 of 13
All specifications subject to change. Consult Tyco Electronics for latest specifications.
AXICOM
Telecom-, Signal and RF Relays
108-98011 Rev. C
Reed V23100-V4 Relay Dimensions DIP version (flat)
DIP flat version L W H Hb T Tw Tz mm 19.30 - 0.2 6.40 - 0.2 5.70 - 0.2 5.10 - 0.2 3.20 0.1 0.50 0.1 0.25 0.1 inch 0.760 - 0.008 0.252 - 0.008 0.224 - 0.008 0.201 - 0.008 0.126 0.004 0.020 0.004 0.010 0.004
Dimensions in mm
Mounting hole layout
Top view
Terminal assignment
Top view 1 form a standard A000 1 form a with diode A010 1 form a with electrostatic shield and diode A011 1 form c standard C000 1 form a with electrostatic shield A001
14 13 98
12
67
All specifications subject to change. Consult Tyco Electronics for latest specifications.
4 of 13
AXICOM
Telecom-, Signal and RF Relays
108-98011 Rev. C
Reed V23100-V4 Relay Coil Data (values at 23 C)
Nominal voltage Unom Operate/set voltage range Release/ reset voltage Minimum Coil power Coil Resistance
Ordering Information
Relay code Tyco part number
Minimum voltage Umin Vdc 5 12 15 24 5 12 15 24 5 12 15 24 5 12 15 24 5 12 15 24 Vdc 3.5 8.4 10.5 16.8 3.5 8.4 10.5 16.8 3.5 8.4 10.5 16.8 3.5 8.4 10.5 16.8 3.5 8.4 10.5 16.8
Maximum voltage Umax Vdc 22 33 44 44 14 25 47 47 13 (14.5)* 22 (23.5)* 44 (14.5)* 44 (49.0)* 22 33 44 44 14 25 47 47 Vdc 0.75 1.80 2.25 3.60 0.75 1.80 2.25 3.60 0.75 1.80 2.25 3.60 0.75 1.80 2.25 3.60 0.75 1.80 2.25 3.60 mW 50 144 112 288 50 144 112 288 125 288 112 288 50 144 112 288 50 144 112 288 / 10 % 500 1000 2000 2000 500 1000 2000 2000 200 500 2000 2000 500 1000 2000 2000 200 1000 2000 2000 V23100-V4005-A000 V23100-V4012-A000 V23100-V4015-A000 V23100-V4024-A000 V23100-V4005-A010 V23100-V4012-A010 V23100-V4015-A010 V23100-V4024-A010 V23100-V4305-C000 V23100-V4312-C000 V23100-V4315-C000 V23100-V4324-C000 V23100-V4005-A001 V23100-V4012-A001 V23100-V4015-A001 V23100-V4024-A001 V23100-V4005-A011 V23100-V4012-A011 V23100-V4015-A011 V23100-V4024-A011 1393763-1 1393763-6 1-1393763-0 1-1393763-4 1393763-4 1393763-8 1-1393763-2 1-1393763-6 2-1393763-0 2-1393763-8 3-1393763-4 4-1393763-0 1393763-3 1393763-7 1-1393763-1 1-1393763-5 1393763-3 1393763-9 1-1393763-3 1-1393763-7
DIP version flat: 1 form a contact, standard
DIP version flat: 1 form a contact, with diode
DIP version flat: 1 form c contact, standard
DIP version flat: 1 form a contact, with electrostatic shield
DIP version flat: 1 form a contact, with electrostatic shield and diode
* Values in brackets refer to high relay with protective diode
Relay Code
Digit Basic type number of DIL/SIL reed relay Contact arrangement 0 = DIL: 1 form A 3 = DIL: 2 form A or 1 form C 5 = SIL: 1 form A 6 = Mini SIL: 1 form A Coil number 05 = 5 Vdc coil 12 = 12 Vdc coil 15 = 15 Vdc coil 24 = 24 Vdc coil Relay version (contact arrangement)
Ordering example: V23100-V4005-A010 DIL reed relay with 1 make, 5 V nominal voltage, with clamping diode (spark suppression) All specifications subject to change. Consult Tyco Electronics for latest specifications.
Block 1 123456 V23100
-
Block 2 7 8 9 10 11 V4
Block 3 12 13 14 15
5 of 13
AXICOM
Telecom-, Signal and RF Relays
108-98011 Rev. C
Reed V23100-V4 Relay Dimensions DIP version (high)
DIP-high version L W H S T Tw Tz mm 19.30 - 0.2 7.00 - 0.2 7.50 - 0.2 0.50 0.1 3.20 0.1 0.50 0.1 0.25 0.1 inch 0.760 - 0.008 0.276 - 0.008 0.295 - 0.008 0.200 0.004 0.126 0.004 0.020 0.004 0.010 0.004
Dimensions in mm
Mounting hole layout
Top view
Terminal assignment
Top view 2 form a standard B000 1 form c with diode C010 2 form a with diode B010 1 form c with electrostatic shield and diode C011
All specifications subject to change. Consult Tyco Electronics for latest specifications.
6 of 13
AXICOM
Telecom-, Signal and RF Relays
108-98011 Rev. C
Reed V23100-V4 Relay Coil Data (values at 23 C)
Nominal voltage Unom Operate/set voltage range Release/ reset voltage Minimum Coil power Coil Resistance
Ordering Information
Relay code Tyco part number
Minimum voltage Umin Vdc 5 12 15 24 5 12 15 24 5 12 15 24 5 12 15 24 Vdc 3.5 8.4 10.5 16.8 3.5 8.4 10.5 16.8 3.5 8.4 10.5 16.8 3.5 8.4 10.5 16.8
Maximum voltage Umax Vdc 14 25 47 47 14 25 47 47 14.5 23.5 14.5 49.0 14.5 23.5 14.5 49.0 Vdc 0.75 1.80 2.25 3.60 0.75 1.80 2.25 3.60 0.75 1.80 2.25 3.60 0.75 1.80 2.25 3.60 mW 125 288 112 288 125 288 112 288 125 288 112 288 125 288 112 288 / 10 % 200 500 2000 2000 200 500 2000 2000 200 500 2000 2000 200 500 2000 2000 V23100-V4305-B000 V23100-V4312-B000 V23100-V4315-B000 V23100-V4324-B000 V23100-V4305-B010 V23100-V4312-B010 V23100-V4315-B010 V23100-V4324-B010 V23100-V4305-C010 V23100-V4312-C010 V23100-V4315-C010 V23100-V4324-C010 V23100-V4305-C011 V23100-V4312-C011 V23100-V4315-C011 V23100-V4324-C011 1-1393763-8 2-1393763-6 3-1393763-2 3-1393763-8 1-1393763-9 2-1393763-7 3-1393763-3 3-1393763-9 2-1393763-2 3-1393763-0 3-1393763-6 4-1393763-2 2-1393763-3 3-1393763-1 3-1393763-7 4-1393763-3
DIP version high: 2 form a contact, standard
DIP version high: 2 form a contact, with diode
DIP version high: 1 form c contact, with diode
DIP version high: 1 form c contact, with diode and electrostatic shield
UI
=
Minimum voltage at 23 C after preenergizing with nominal voltage without contact current Maximum continous voltage at 23 C
UII
=
The operating voltage limits UI and UII depend on the temperature according to the formula: UI tamb =
and
KI * UI 23 C KIl * UIl 23 C Ambient temperature Minimum voltage at ambient temperature, tamb Maximum voltage at ambient temperature, tamb Factors (dependent on temperature), see diagram
UII tamb = tamb = UI tamb = UII tamb = kI , kII Ambient temperature tamb [C] =
All specifications subject to change. Consult Tyco Electronics for latest specifications.
7 of 13
AXICOM
Telecom-, Signal and RF Relays
108-98011 Rev. C
Reed V23100-V4 Relay Dimensions SIL version
SIL version L W H T Tw Tz mm 19.80 - 0.2 5.08 - 0.2 7.80 - 0.2 3.50 0.2 0.60 0.1 0.25 0.1 inch 0.780 - 0.008 0.200 - 0.008 0.307 - 0.008 0.138 0.008 0.024 0.004 0.010 0.004
Dimensions in mm
Mounting hole layout
Top view
Terminal assignment
Top view 1 form a standard A000 1 form a with diode A010
All specifications subject to change. Consult Tyco Electronics for latest specifications.
8 of 13
AXICOM
Telecom-, Signal and RF Relays
108-98011 Rev. C
Reed V23100-V4 Relay Coil Data (values at 23 C)
Nominal voltage Unom Operate/set voltage range Release/ reset voltage Minimum Coil power Coil Resistance
Ordering Information
Relay code Tyco part number
Minimum voltage Umin Vdc 5 12 15 24 5 12 15 24 Vdc 3.5 8.4 10.5 16.8 3.5 8.4 10.5 16.8 SIL version: 1 form a contact
Maximum voltage Umax Vdc 22 33 44 44 22 33 44 44 Vdc 0.75 1.80 2.25 3.60 0.75 1.80 2.25 3.60 mW 50 144 112 288 50 144 112 288 / 10 % 500 1000 2000 2000 500 1000 2000 2000 V23100-V4505-A000 V23100-V4512-A000 V23100-V4515-A000 V23100-V4524-A000 V23100-V4505-A010 V23100-V4512-A010 V23100-V4515-A010 V23100-V4524-A010 4-1393763-4 4-1393763-7 4-1393763-9 5-1393763-1 4-1393763-5 4-1393763-8 5-1393763-0 5-1393763-2
SIL version: 1 form a contact with diode
All specifications subject to change. Consult Tyco Electronics for latest specifications.
9 of 13
AXICOM
Telecom-, Signal and RF Relays
108-98011 Rev. C
Reed V23100-V4 Relay Dimensions Mini SIL version
SIL version L W H Tw Tz mm 15.20 - 0.2 3.80 - 0.2 6.80 - 0.2 0.50 0.1 0.25 0.1 inch 0.780 - 0.008 0.200 - 0.008 0.307 - 0.008 0.024 0.004 0.010 0.004
Dimensions in mm
Mounting hole layout
Top view
Terminal assignment
Top view 1 form a standard A000 1 form a with diode A010
Coil Data (values at 23 C)
Nominal voltage Unom Operate/set voltage range Release/ reset voltage Minimum Coil power Coil Resistance
Ordering Information
Relay code Tyco part number
Minimum voltage Umin Vdc Vdc SIL version: 1 form a contact 5 3.5 12 8.4
Maximum voltage Umax Vdc 13.6 21.6 Vdc 0.75 1.80 0.75 1.80 mW 50 205 50 205 / 10 % 500 700 500 700 V23100-V4605-A000 V23100-V4612-A000 V23100-V4605-A010 V23100-V4612-A010 1422026-2 1422026-3 1422026-5 1422026-6
SIL version: 1 form a contact with diode 5 3.5 13.6 12 8.4 21.6
All specifications subject to change. Consult Tyco Electronics for latest specifications.
10 of 13
AXICOM
Telecom-, Signal and RF Relays
108-98011 Rev. C
Reed V23100-V4 Relay Contact Data
Type of relay Type of contact/s Contact material Maximum continuous current Maximum switching current Maximum switching voltage at nominal voltage: 5 Vdc 12-24 Vdc Maximum switching capacity DC voltage AC voltage Initial contact resistance / measuring condition: Electrical endurance at 12 V / 10 mA at 24 V / 400 mA 1A 0.5 A 200 Vdc / Vac peak 200 Vdc / Vac peak 10 W 10 VA 1 form a DIP version 2 form a 1 form c Ruthenium 1.2 A 0.25 A 175 Vdc 175 Vdc peak 3W 3 VA <150 m 5 x 107 5 x 106 1A 0.5 A 200 Vdc / Vac 200 Vdc / Vac 10 W 10 VA 1A 0.5 A 200 Vdc / Vac peak 200 Vdc / Vac peak 10 W 10 VA SIL version 1 form a Mini SIL Version 1 form a
Insulation
Insulation resistance at 500 Vdc Dielectric test voltage (1 min) contact / coil contact / contact 1500 Vdc 250 Vdc contact coil > 109 1500 Vdc 200 Vdc 1500 Vdc 250 Vdc 1500 Vdc 225 Vdc
High Frequency Data
Capacitance between coil and contacts between adjacent contact sets between open contacts max. 2 pF max. 1 pF max. 1 pF
General Data
Type of relay Type of contact/s Maximum operate time (including bounce) Maximum release time Operating temperature range Storage temperature Thermal resistance Maximum permissible coil temperature Vibration resistance (function) Shock resistance, half sinus, 11 ms Degree of protection Mounting position Resistance to soldering heat 1 form a DIP version 2 form a 0.75 ms 0.15 ms SIL version 1 form c 1 form a 1.1 ms 0.75 ms 1.6 ms 0.15 ms -40 C ... +85 C -40 C ... + 95 C Approx. 75 K / W 105 C 30 G 30 G 50 to 2000 Hz 10 to 2000 Hz 50 G 150 G immersion cleanable, IP 67 any 265 C / 10 s Mini SIL Version 1 form a 0.75 ms 0.15 ms
30 G 10 to 2000 Hz 150 G
30 G 10 to 2000 Hz 50 G
All specifications subject to change. Consult Tyco Electronics for latest specifications.
11 of 13
AXICOM
Telecom-, Signal and RF Relays
108-98011 Rev. C
Reed V23100-V4 Relay
IM Relays
4th generation slim line - low profile polarized 2 c/o telecom signal relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 1.5 ... 24 V, coil power consumption of 50 ... 200 mW, latching relays with 1 coil 100 mW. The IM relay is available as through hole and surface mount type (J-Legs and Gull Wings) and capable to switch loads up to 60 W/62,5 VA. It is currently the only 2 A rated 4G relay on the market. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The IM relay is tested according CECC/IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 10 x 6 mm board space and 5.65 mm height.
D2n Relays
2nd generation non polarized 2 c/o relay for telecom and various other applications. Nominal voltage range from 3 ... 48 V, coil power consumption from 150 .... 500 mW. The D2n relay is capable to switch currents up to 3 A. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV - 10 / 160 s). Dimensions approx. 20 x10 mm board space and 11 mm height.
P1 Relays
Extremely sensitive, polarized 1 c/o relay with bifurcated contacts for a wide range of applications, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power consumption 65 mW, latching relays with 1 coil 30 mW. The P1 relay is available as through hole or surface mount type and capable to switch currents up to 1 A. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV - 10 / 160 s). Dimensions approx. 13 x 7,6 mm board space and 7 mm height for THT or 8 mm height for SMT version.
P2 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power consumption 140 mW, latching relays with 1 coil 70 mW. The P2 Relay is available as through hole or surface mount type and capable to switch currents up to 5 A. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The P2 relay is tested according CECC/IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm board space and 10 mm height.
W11 Relays
Low cost, non polarized 1 c/o relay for various applications. Nominal voltage range from 3 ... 24 V, coil power consumption 450 mW, sensitive versions 200 mW. The W11 relay is capable to switch currents up to 3 A. Dielectric strength 1000 Vrms. Dimensions approx. 15,6 x 10,6 mm board space and 11,5 mm height.
FX2 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for the high sensitive version, 140... 300 mW for the standard version, latching relays with 1 coil 100 mW. The FX2 relay is available as through hole type and capable to switch loads up to 60 W/62,5 VA. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The FX2 relay is tested according CECC/ IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm board space and 10,7 mm height.
Reed Relays
High sensitive, non polarized relay for telecom and various other applications, available with 1 n/o, 2 n/o or 1c/o contacts. Nominal voltage range from 5 ... 24 V, coil power consumption 50...280 mW for 1 n/o and 125 ... 280 mW for 2 n/o or 1 c/o versions. Reedrelays are available in DIP or SIL housing and capable to switch currents up to 0,5 A. Integrated diode and/or electrostatic shield optional. Dielectric strength 1500 Vdc. Dimensions approx. 19,3 x 7 mm board space and 5 ... 7,5 mm height for DIP or 19,8 x 5 mm board space and 7,8 mm height for SIL version.
FT2 / FU2 Relays
3rd generation non polarized, non latching 2 c/o telecom relay with bifurcated contacts. Nominal voltage range from 3 ... 48 V, coil power consumption 200 ... 300 mW. Most sensitive 48 V relay. Available as through hole and surface mount type. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The FT2/FU2 relay is tested according CECC/IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm board space and 10 mm height.
Cradle Relays
Extremely reliable and mature relay family of 1st generation for various signal switching applications. Available as non polarized, polarized / latching and relay with AC coil. The benefit is the possibility of combining various contact sets from 1 up to 6 poles, single and bifurcated contacts, different contact materials with a coil voltage range from 1,5 Vdc to 220 Vac. Cradle relays are available as dust protected and hermetically sealed versions, with plug in or solder terminals and are capable to switch currents up to 5 A. Forcibly guided (linked) contact sets optional. Dielectric strength 500 Vrms. Dimensions from approx. 19 x 24 to 19x35 mm board space and 30 mm height.
FP2 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for the high sensitive version, 140... 300 mW for the standard version, latching relays with 1 coil 100 mW.. The FP2 Relay is available as through hole type and capable to switch loads up to 60 W/62,5 VA. Dielectric strength fulfills FCC part 68 (1,5 kV - 10 / 160 s). The FP2 is tested according CECC/IECQ approved. Dimensions approx. 14 x 9 mm board space and 5 mm height.
Other Relays
We offer a variety of different relay families for maintenance and replacement purposes. These relays are up to 60 years old now, such as Card Relay SN (V23030 series), Small General Purpose Relay (V23006 series), Small Polarized Relay (V23063 ... V23067 and V23163 ... V23167 series). Accessories like sockets, hold down springs, etc. optional.
High Frequency Relays
HF3 / HF3S / HF6 series RF relays offering excellent RF characteristics in a small package. All HF series relays are suitable for SMD soldering processes. Available as non latching or latching versions with 1 or 2 coils and a nominal coil voltage range from 3 ... 24 V, a coil power consumption of 140 mW or 70 mW (single coil latching types). HF3: Low cost RF relay suitable up to 3 GHz. Impedance 50 and 75 Ohm. 50 W hot switching and 50 W RF power carry capability. Dimensions 14.6 x 7.3 x 10.3 mm. HF3S: High performance, high power RF relay suitable up to 3 GHz, 50 W hot switching and 150 W RF power carry capability. Dimensions 15 x 7.6 x 10.6 mm. HF6: High performance, high power RF relay suitable up to 6 GHz, 50 W hot switching and 50 W RF power carry capability. Dimensions 15 x 7.6 x 10.6 mm.
MT2
2nd generation non polarized, non latching 2 c/o telecom and signal relay with bifurcated contacts. Nominal voltage range from 3 ... 48 V, coil power consumption 150/200/300/400 and 550 mW. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV - 10 / 160 s). Dimensions approx. 20 x 10 mm board space and 11 mm height.
All specifications subject to change. Consult Tyco Electronics for latest specifications.
12 of 13
AXICOM
Telecom-, Signal and RF Relays
Reed V23100-V4
Tyco Electronics Logistics AG Werk RelayAxicom Au Seestrasse 295 CH-8804 Au-Wadenswil / Switzerland Phone +41 44 782 91 11 Fax +41 44 782 90 00 E-mail: axicom@tycoelectronics.com
108-98011 Rev. C
Tyco Electronics Paulsternstrasse 26 D-13629 Berlin / Germany Phone +49 30 386 38573 Fax +49 30 386 38575 E-mail: axicom@tycoelectronics.com
Tyco Electronics EC Trutnov s.r.o. Komenskeho 821 CZ-541 01 Trutnov / Czech Republic E-mail: axicom@tycoelectronics.com
Telecom-, Signal and RF Relays
AXICOM
Tyco Electronics Corporation POB 3608, Harrisburg, PA 17105, USA Phone +1 800-522-6752


▲Up To Search▲   

 
Price & Availability of V23100-V4005-A000

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X